Item
|
Data
|
APPROVAL
|
Certification Link | Certification Link
|
Test standard
|
IEC/EN61984:2009 / UL1059
|
Pitch [mm]
|
7.5/7.62
|
Poles
|
2-12P
|
EN61984 Test data
|
VDE certificate NO. 40030786
|
Rated voltage [V]
|
400
|
Rated current [A]
|
20
|
Rated connection capacity(solid/stranded) [mm2]
|
0.2-2.5
|
Surge voltage category/pollution degree/material group
|
III/3/I
|
Rated impulse voltage [KV]
|
4.0
|
Rated torque [N·m]
|
/
|
UL1059Test data
|
UL File Number E228872
|
Use group
|
B
|
C
|
D
|
Rated voltage [V]
|
300
|
300
|
300
|
Rated current [A]
|
15
|
15
|
10
|
(Rated connection capacity) (solid/stranded) [AWG]
|
22-14
|
Rated torque [Lb. in]
|
/
|
General data
|
/
|
Screw
|
/
|
Inflammability classUL94
|
V-0
|
Ambient temperature [℃]
|
-40~+105
|
Relative humidity
|
5%-95%
|
Inspection standard
|
MIL-STD-105E II
|
AQL
|
0.65
|
Warranty
|
12 months
|
Material and plating
|
/
|
Housing
|
PA66
|
Spring
|
Stainless
|
Contact
|
Copper alloy,Sn plated
|
Wire connecting
|
8-9mm; Recommended stripping length 8-9mm;
|
1.)Solid wire: After stripping corresponds to the length of the wire , put the wire into the hole after using the accessory depress the cage spring ;
|
2.)Strand wire :After stripping corresponds to the length of the wire, can be directly connected or use of the corresponding standard insulated ferrule , then put the wire into the hole after using the accessory press the cage spring ;
|